6 Easy Steps to Install
ANTI-WASHIGEOJUTE
- Prepare the soil by grading or raking area free of clods
and large stones. Do not compact. If using fertilizer, add
it to soil before grading.
- Seeds and mulch (if required) should be distributed evenly
over the prepared soil.
- ANTI-WASHIGEOJUTE should be applied by unrolling down
the slope or in the direction of water flow. Always bring
ANTI-WASHIGEOJUTE down to level area before termination,
fold 6" under, and secure with staples.
- Secure ANTI-WASHIGEOJUTE at the top of the slope by
toeing it in 6" deep. Reinforce with a row of at least
five (5) staples, spacing each about a foot apart, and covering
with soil.
- Place staples 18" to 24" apart throughout to
secure matting to ground. All staples must be driven flush
with soil surface.
- Always overlap the edges 2" to 6". At the end
of each roll, fold back 4" to 8" of the matting.
Overlap this 4" to 8" over the start of the next
roll. Securely staple the two layers to the ground.
Remember to lay ANTI-WASHIGEOJUTE
loosely,
Do Not Stretch!
Waterway Installation
1. Always lay jute in the direction
of water flow.
2. Extra staples are needed
in waterways. Staples must be driven flush with soil surface.
3. Check slots should be placed every 25' o 50', depending
on the velocity of the water flow. A row of staples should
be placed on either side of the check slot.
4. Provide drains as needed.
Helpful Hints
- Keep
dry in storage
- Remember to lay ANTI-WASH/GEOJUTE loosely; DO NOT STRETCH!
- Check slots may be needed on steep slopes to prevent subsurface
movement of soil during prolonged or heavy rains.
To establish
a slot:
- Dig 6" deep trench perpendicular to water flow.
- Roll ANTI-WASH/GEOJUTE in two or three folds (see diagram)
and set into trench.
- Staple fabric securely in bottom of trench and continue
rolling down hill.
- Because ANTI-WASH/GEOJUTE has 60 to 65% of open area,
additional seed can be broadcast over the matting to cover
bare spots that may appear due to improper seeding or poor
germination.
- Recommended usage: Approximately 200 staples per 100 sq.
yds.
Always check with state or contracting agency
for installation specifications or special requirements
|
Specifications
|
Property
|
Test Method
|
Typical Value
|
Eng. / Metric Units
|
Yarn Fiber
|
|
woven jute, undyed & unbleached
|
Yarn count - warp
|
|
78 per width, minimum
|
Yarn count -weft
|
|
42 per linear yard, minimum
|
Color
|
|
Natural (Brown, Earth Tone)
|
Fabric width
|
|
48" / 1.23 m
|
inches/ meters
|
Fabricweight
|
|
.921bs / 417g
|
lbs/yd2 - g/m2
|
Strands per ft/mtr - warp
|
A5TM D-3775
|
19.5 / 63.5
|
-
|
Strands per ft/mtr - weft
|
A5TM D-3775
|
14.0 / 45.0
|
-
|
Mass per unit Area
|
A5TM D-3776 warp
|
14.7 / 490
|
oz /yd2 - g/m2
|
Grab Tensile - Dry
|
A5TM D-4632 warp
(modified) Fill
|
300 / 1.38
175 / .70
|
lbs/ft - KN
lbs/ft - KN
|
Grab Tensile - wet
|
A5TM D-4632 warp
(modified) Fill
|
125 / .50
65 / .28
|
lbs/ft - KN
lbs/ft - KN
|
Elongation at Break
|
A5TM D-4632 warp
(modified) Fill
|
10
10
|
%
%
|
Open Area
Durability
Water velocity
Unit shear Test
|
C.O.E. CW002215.
Field Experience
university channel Test
-
|
60-65
1-2
8 / 2.4
0.45
2.20
|
%
Years
ft/sec - m/sec
lbs/ft2
kg/m2
|
"C" Factor (1.5:1 slope)
|
-
|
.005
|
-
|
Staples
Type
|
Weight /Carton
|
Metric Units KG
|
Staples Per Carton
|
11 guage 6"
|
43lbs.
|
19.5
|
1000
|
8 guage 6"
|
39lbs.
|
17.7
|
500
|
8 guage 8"
|
50lbs.
|
22.7
|
500
|
Typical usage: Approximately 200 staples per
Roll. Other lengths of staples available on request.
Roll Packaging:
Available in regular and smolder resistant
rolls call or write for current product data sheet on smolder
resistant rolls
Width x Length
|
Type
|
Area
|
Weights
|
English
|
Metric
|
|
Sq. Yards
|
Sq. Mtrs.
|
English
|
Metric
|
48" x225
|
1.22 x 68.6
|
Regular
|
100
|
83.6
|
92 lbs.
|
41.7 KG.
|
48" x225
|
1.22 x 68.6
|
smolder Resistant
|
100
|
83.6
|
97 lbs.
|
44.0 KG.
|
48" x147
|
1.22 x 44.8
|
UPS size roll
|
65
|
54.3
|
60 lbs.
|
27.2 KG.
|
The information presented herein, while not guaranteed, is
to the best of our knowledge true and accurate. tucept when
agreed to in writing for specific conditions of use, no warranty
or guarantee expressed or implied is wade regarding the performance
of any product, since the manner of use and handling are beyond
our control. Nothing contained herein is to be construed as
permission or as a recommendation to infringe any patent.
|
|
|
|
|
 |
|
|